BAL-29 roof infill strips

BAL-29 roof infill strips

Regular price $7.49 AUD
Regular price Sale price $7.49 AUD
Sale Sold out
View full details

 Ember attack simulation video



 

BAL-29  Roof infill strips

Meets BAL-29 (AS 3959) requirements as a fire resistant seal.

Conforms  to  AS 1530.3 1999 “non ignitability" fire rating and was tested by a NATA certified laboratory.

We can manufacture any profile so please contact us if the profile you require is not shown here.

If you are unsure of what Bushfire attack level (BAL) your structure is, the CSIRO have an excellent assessment tool & that can be found at "

https://best-practices-assessment-tool.herokuapp.com/calculator?slope=5&vegslope=5&FFDI=80&vegtype=Shrubland *

*

*(when using the above assessment please refer below for the correct FDI for your area)

Average annual accumulated FDI across Australia

State or Territory Region Fire Danger Index*
Australian Capital Territory All 100
New South Wales Alpine areas 50
Greater Hunter, Greater Sydney, Illawara, Far South Coast and Southern ranges 100
New South Wales (excluding alpine areas and the Greater Hunter, Greater Sydney, Illawarra/Shoalhaven, Far South Coast and Southern Ranges) 80
Northern Territory All 40
Queensland All 40
South Australia All 80
Tasmania All 50
Victoria Alpine areas 50
Victoria (excluding alpine areas) 100
Western Australia All 80

*These values were provided by the Australasian Fire and Emergency Service Authorities Council. Alpine and sub-alpine areas are defined as per the National Construction Code. The FDI at your location can be refined in consultation with a relevant regulatory authority if local climate data can be provided.

 


BAL-29  Gap filler / Sealing strip 

 Seals gaps under flashings or around windows where they meet cladding. They can be fitted on the vertical or under an overhanging surface (either the fascia or around a window frame) because of the self adhesive backing.

Can be used to fill any gaps behind barge boards at the edges of tiled or metal roofs

 Can be used to seal the bottom of metal cladding where it sits on a concrete slab, or under roof domes, roof skylights or any vents.

 Can be used as a channel foam to protect against embers piling up on top of an awning in the small space under the eaves.

Can be used as a fire resistant seal which accommodates expansion & contraction due to temperature variations or movement or to seal any gap.

Conforms to AS 1530.3 1999 “non ignitability" fire rating & was tested by a NATA certified laboratory.

Other Gap filler /  sealing strip dimensions are available if required. Contact us for a quote

 

                                         

                     1. Specifications for infill strips

                 2. Installation instructions for existing roofs

 

BAL-29 products must be installed as per AS 3959 requirements. Please note that some  individual councils may require additional metal flashing to be included when installing these infills. Please check if your local council requires this extra flashing.

 